Smart Distribution Panel Meters


Invendis Smart multifunction distribution panel meters monitors and measures all electrical parameters such as voltage, current, power factor, active power, apparent power, reactive power, Active energy etc. Our meters facilitate distribution panels with exact, accurate and reliable measurements.


ET - 3010


Counter Type Energy Meters for Generator and Sub Metering


Accumulated value of energy of linked electrical load


Usage :

Distribution panels/ Electrical panels


Monitoring and maintenance of electrical systems

Technical Specifications


Configuration: 3 Phase, 3 Element, 1 Phase or 3 Phase Nominal: 415v LT (L-L)

Input current: Factory set


Temperature: 0-50° C


Accuracy:
-- ± (0.5% of FS + 0.5% of Rdg + 1 digit)
-- ± 1.0% of FS for Current

Range - 80% to 120% of Nominal


Humidity: <95% non-condensing


Mounting: Slide and Lock clamp

Warranty: 15 months from date of Manufacturer OR 12 months from date of sale, whichever is earlier


ET - 4001


Multi-function meter for power distribution panels

voltage, current, frequency, power and energy of the linked electrical load.

Suitable for 1Ph- 2Wire / 3P 3 wire -3P 4 wire system.

Can sense current from external CT (configurable)

Accurate & Reliable with RMS measurement

Usage :

Electrical distribution panel to manage power distribution.

Sub metering and can be used for billing tenants.

Centralised Power management when interfaced with SCADA / Dataloggers.

Technical Specifications

Configuration: 1/3 Phase, 3 Element; 3 / 4 Wire (Note Order code)

Input V Nominal: 415 V LT or 110 V through PT (line to line)

Accuracy:
-- ± (0.5% of FS + 0.5% of Rdg + 1 digit)
-- ± 0.2% for Frequency
-- ± 1.0% of FS for Current

Isolation: 2000 V AC for one minute

Display: Displays of 3-digit, 12.5 mm, 7 segment, super-bright LEDs / LCD Display

Safety: Measurement Category III, Pollution Degree 2 as per EN61010-1 First Edition

Frequency: 0.1 Hz

Power: autoscaling depending on input

Power Factor: 0.01

Energy: 1 kWH upto 866 kW

10 kWH above 866 kW


ET - 4021


Multi-function meter for power distribution panels

RS232 communication for meter and the data logger / PLC.

voltage, current, frequency, power and energy of the linked electrical load

Suitable for 1Ph- 2Wire / 3P 3 wire -3P 4 wire system.

Can sense current from external CT (configurable)

Accurate & Reliable with RMS measurement

Usage :

Electrical distribution panel to manage power distribution.

Sub metering and can be used for billing tenants.

Centralised Power management when interfaced with SCADA / Dataloggers.

Technical Specifications

Configuration: 1/3 Phase, 3 Element; 3 / 4 Wire (Note Order code)

Input V Nominal: 415 V LT or 110 V through PT (line to line)

Input I Nominal: 5 A or 1 A through CT

Computation: True RMS for all Power & Energy Parameters

Accuracy:
-- ± (0.5% of FS + 0.5% of Rdg + 1 digit)
-- ± 0.2% for Frequency
-- ± 1.0% of FS for Current

Isolation: 2000 V AC for one minute

Safety: Measurement Category III, Pollution Degree 2 as per EN61010-1 First Edition

Frequency: 0.1 Hz

Power: autoscaling depending on input

Power Factor: 0.01

Aux Supply: 85 - 270 V AC or DC

Energy: Increments 1 kWH upto 866 kW and 10 kWH above 866 kW

RS232 Serial Interface for external system interfacing.

Dimension: 96 x 96 mm (Bezel), x 52 mm

Mounting: Slide and Lock clamp

Ambient: Temp. 0-50 deg C, RH < 95% non-condensing


ET - 4041


Multi-function meter for power distribution panels

Serial communication for data logger interface.

Voltage, current, frequency, power and energy of the linked electrical load

Suitable for 1Ph- 2Wire

Can sense current from external CT (configurable) – 5 A or 1 A through CT

AAccurate & Reliable with RMS measurement

Usage :

Electrical distribution panel to manage power distribution.

Sub metering and can be used for billing tenants.

Centralised Power management when interfaced with SCADA / Dataloggers.

Technical Specifications

Configuration: 1/3 Phase

Input V Nominal: 415 V LT (Line to Line)

Input I Nominal: 5 A or 1 A through CT

Computation: True RMS for all Power & Energy Parameters

Accuracy:
-- ± (0.5% of FS + 0.5% of Rdg + 1 digit)
-- ± 0.2% for Frequency
-- ± 1.0% of FS for Current

Isolation: 2000 V AC for one minute

Safety: Measurement Category III, Pollution Degree 2 as per EN61010-1 First Edition

Frequency: 0.1 Hz

Power: autoscaling depending on input

Power Factor: 0.01

Aux Supply: 85 - 270 V AC or DC

Energy: Increments 1 kWH upto 866 kW and 10 kWH above 866 kW

RS232 Serial Interface for external system interfacing.

Dimension: 96 x 96 mm (Bezel), x 52 mm

Mounting: Slide and Lock clamp

Ambient: Temp. 0-50 deg C, RH < 95% non-condensing


ET – 5001


Multi-function meter for power distribution panels

Serial communication for data logger interface.

Optional BACnet port and measurement of Max. Demand and THD of the system.

Voltage, current, frequency, power, and energy of the linked electrical load

Suitable for 1Ph- 2Wire / 3P 3 wire -3P 4 wire system.

Can sense current from external CT (configurable) – Supports 20A

Usage :

Electrical distribution panel to manage power distribution.

Find application in Energy Management with analysis considering Maximum Demand, THD and its effects.

Sub metering and can be used for billing tenants.

Centralised Power management when interfaced with SCADA / Dataloggers

Technical Specifications

Configuration: 1/3 Phase, 3 Element; 3 / 4 Wire (Note Order code)

Input V Nominal: 415 V LT or 110 V through PT (line to line)

Input I Nominal: 5 A or 1 A through CT

Computation: True RMS for all Power & Energy Parameters

Supports Demand computation and captures Max Demand.

Accuracy:
-- ± (0.5% of FS + 0.5% of Rdg + 1 digit)
-- ± 0.2% for Frequency
-- ± 1.0% of FS for Current

Isolation: 2000 V AC for one minute

Safety: Measurement Category III, Pollution Degree 2 as per EN61010-1 First Edition

Frequency: 0.1 Hz

Power: autoscaling depending on input

Power Factor: 0.01

Aux Supply: 85 - 270 V AC or DC

Energy: Increments 1 kWH upto 866 kW and 10 kWH above 866 kW

RS485 / BACnet Interface for external system interfacing.

Dimension: 96 x 96 mm (Bezel), x 52 mm

Mounting: Slide and Lock clamp

Ambient: Temp. 0-50 deg C, RH < 95% non-condensing

Ranges

Applications / Usage


Motor control centres


Control Panels


Genset Panels


Power distribution panels